Pressure
Reducing Valve [DP 13]
::: |
Pressure Reducing Valve [DP 13] |
|
Description:
DP 13 is
a Cast Iron pilot operated pressure
reducing valve suitable for steam or compressed air.
Note: For steam : IBR / NIBR, For Air: NIBR
Available Sizes & Pipe Connections:
15, 20, 25, 40 & 50 NB
Screwed : BSPT / NPT for 15,20 & 25 NB
Flanged : BS 10 Table 'F/H' for 40 & 50 NB
Limiting Conditions :
PMO - Maximum allowable Pressure : 13.00 kg / cm2
TMO- Maximum allowable Temperature : 2200C
Cold hydraulic test pressure : 26.00 kg / cm2
Springs as per requirement
Yellow: 0.2 Bar to 3.0 Bar
Blue : 2.5 Bar to 7.0 Bar
Red : 6.0 Bar to 13.0 Bar
Std. Acc.: Pr. Gauge, Syphon & Gauge Cock
Pressure Sensing Pipe:
The DP 13 controls the pressure by sensing the
downstream pressure through a pressure sensing
pipe taken to the union (item 27) or through the
internal sensing pipe (item 19) Fitting of the external
pressure sensing pipe is described in the User Manual
supplied with the valve.
Note : Capacity is reduced and there is a
possibility
of hunting if an external pressure sensing pipe is not
fitted
Installation :
The valve should be installed in a horizontal
pipeline
with direction of flow as indicated by the arrow on
the valve body. Full instructions are given in the
User Manual supplied with the Valve.
Dimensions : (approx.) mm (Refer Flg. 1 & 2)
|
Size |
A |
B |
C |
D |
E |
|
15 |
69 |
181 |
86 |
160 |
237 |
|
20 |
69 |
181 |
86 |
160 |
237 |
|
25 |
79 |
203 |
100 |
180 |
247 |
|
40 |
96 |
251 |
153 |
212 |
359 |
|
50 |
96 |
251 |
178 |
232 |
359 |
|
Genera;
tolerance up to 25 NB + 4
Above 25 mm + 7 |
|


|

 |
|
|
Regd.
Office : 207, 2 nd Floor, Shankala Industrial Estate, 186, Gogate
Wadi, Goregaon (East),
Mumbai - 400063, Maharashtra, India.
* Tel. : (O) 022-2927
5456 * Telefax : 2927 5509 * Mobile : 9820550115
| * Email :- |
 |
|
|
|